3Pole NS 400N MCCB
Categories
Model Number: Circuit Breaker - 003
Seller: Yueqing Bodun Electric Co., Ltd.
3Pole NS 400N MCCB Comply with IEC60947-2,Up to 1600Amp Thermal Magnetic 3p and 4p
Contact Now3Pole NS 400N MCCB
Model: | NS 400N 3p | ||||||
Approvals: | CE,ISO9001 | ||||||
Brand Name: | DLXELE,DLXIS,MRIKER | ||||||
Region: | Wenzhou Zhejiang | ||||||
Brief Description: | 3Pole NS 400N MCCB Comply with IEC60947-2,Up to 1600Amp Thermal Magnetic 3p and 4p | ||||||
|
|||||||
Support to adjust: | yes | ||||||
Pole: | 3p |
Product Details
Key Specification
BDM2-X Moulded Case Circuit Breaker
New design, Adjustable Amps
Comply with IEC60947-2
Up to 1600Amp
Tripping types:Thermal Magnetic
Amps ranges: 100A, 160A, 250A, 400A, 630A, 800A,1250A, 1600A
Frequency: AC 50/60Hz
Rated operating voltage: 690V and below
Rated insulating voltage: 750V
Poles: 3, 4P
Utilization category: A
Main Technical Specifications |
![]() |
Trip units main technical parameter | |||||||||||||||
Thermal magnetic release | |||||||||||||||
![]() |
|||||||||||||||
![]() |
|||||||||||||||
?Electronic release | |||||||||||||||
BDM2 22SE: protection of low-voltage distribution networks for BDM2-100160250 | |||||||||||||||
![]() |
|||||||||||||||
1. Overload protection with adjustable threshold 2. Short-circuit protection with adjustable threshold 3. Load indication : light at 90% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold |
|||||||||||||||
![]() |
|||||||||||||||
BDM2 22ME: protection of motor for BDM2-100160250 | |||||||||||||||
![]() |
|||||||||||||||
1. Overload protection with adjustable threshold, as defined by IEC60947-4 (2) tripping class 10 2. Short-circuit protection with fixed threshold (13xIr) 3. phase failure protection (tripping time delay between 3.5s-6s) 4. Load indication : dark less than 105% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold |
|||||||||||||||
![]() |
|||||||||||||||
BDM2 23SE: protection of low-voltage distribution networks for BDM2-400630 | |||||||||||||||
![]() |
|||||||||||||||
1. Overload protection with adjustable threshold 2. Short-circuit protection with adjustable threshold 3. Load indication : light at 90% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold |
|||||||||||||||
![]() |
|||||||||||||||
![]() |
|||||||||||||||
1. Overload protection with adjustable threshold, as defined by IEC60947-2 2. Short-circuit protection with adjustable threshold 3. Instantaneous short-circuit protection 4. Earth fault protection with adjustable threshold 5. Load indication : light at 90% of Ir setting threshold; Flashing more than Ir setting threshold 6. Fault indication LEDs indicates the type of fault that caused tripping Overload (LT protection) or abnormal component temperature (>Ir); Short-circuit (ST or instantaneous protection)( >Im); Earth fault (if earth fault protection option is present)(Ig); Microprocessor malfunction (both (>Ir) and ( >Im) LEDs go on ,plus the (Ig) LEDs if earth fault protection option is present ) Battery powered. Spare battery are supplied in an adapter box. When a fault occurs , the LED indicating the type of fault ,lights for about 10 minutes . The information is however stored in memory . The LED can be illuminated by pressing the test pushbutton. The LED automatically goes off and the memory is cleared when the circuit breaker is reset . |
|||||||||||||||
![]() |
|||||||||||||||
BDM2 43ME: protection of motor for BDM2-400630 | |||||||||||||||
![]() |
|||||||||||||||
1. Overload protection with adjustable threshold, as defined by IEC60947-4 (2) tripping class 10A,10 and 20 2. Short-circuit protection with adjustable threshold (6...13xIr) 3. Phase failure protection (built-in electronic release: operates unbalanced single-phase currentat 40% and more than )(tripping time delay 4s?0%),as defined by IEC60947-4.1 4. Load indication : Flashing more than Ir setting threshold 5. Fault indication LEDs indicates the type of fault that caused tripping Overload (LT protection) or abnormal component temperature (>Ir); Short-circuit (ST or instantaneous protection)( >Im); Phase failure (right LED); Microprocessor malfunction ( (>Ir) ( >Im) and phase failure LEDs all go on ) Battery powered. Spare battery are supplied in an adapter box. When a fault occurs ,the LED indicating the type of fault ,lights for about 10 minutes . The information is however stored in memory . The LED can be illuminated by pressing the test pushbutton. The LED automatically goes off and the memory is cleared when the circuit breaker is reset . |
|||||||||||||||
![]()
|
Payment Terms | L/C, T/T |
---|---|
Minimum Order | NO LIMIT |
Lead Time / Delivery Time | 10 Day(s) |
Sample Available | YES |
FOB Port | Ningbo,Wenzhou |
Loading Info | By sea or by air |
Packing Info | Standard export carton or according to the customer's requirements |
Target Market(s) | Africa, Eastern Europe, Latin America, Mainland China, Middle East, Northern Europe, Oceania, South Asia, Southeast Asia, Western Europe |
Related products

NS 1600N Moulded Case Circuit Breaker
Model Number: Circuit Breaker - 005
NS 1600N Moulded Case Circuit Breaker Comply with IEC60947-2,Up to 1600Amp Thermal Magnetic 3p and 4p

GE style AEG mini circuit breaker
Model Number: Circuit Breaker - 004
GE style AEG circuit breaker Short circuit protection and overload protection mini circuit breaker .Easy mounting onto 35mm DIN rail or Panel mounting

BDPX125 Moulded Case Circuit Breaker
Model Number: Circuit Breaker - 001
BDPX125 Moulded Case Circuit Breaker Comply with IEC60947-2,Up to 800Amp Thermal Magnetic 3p,4p