4Pole NS 630N MCCB
Categories
Model Number: Circuit Breaker - 002
Seller: Yueqing Bodun Electric Co., Ltd.
4Pole NS 630N MCCB Comply with IEC60947-2,Up to 1600Amp Thermal Magnetic 3p and 4p
Contact Now4Pole NS 630N MCCB
| Model: | 4Pole NS 630N | ||||||
| Approvals: | CE,ISO9001 | ||||||
| Brand Name: | DLXELE,DLXIS,MRIKER | ||||||
| Region: | Wenzhou Zhejiang | ||||||
| Brief Description: | 4Pole NS 630N MCCB Comply with IEC60947-2,Up to 1600Amp Thermal Magnetic 3p and 4p | ||||||
|
|||||||
| Support to adjust: | yes | ||||||
| Pole: | 3p | ||||||
Product Details
Key Specification
BDM2-X Moulded Case Circuit Breaker
New design, Adjustable Amps
Comply with IEC60947-2
Up to 1600Amp
Tripping types:Thermal Magnetic
Amps ranges: 100A, 160A, 250A, 400A, 630A, 800A,1250A, 1600A
Frequency: AC 50/60Hz
Rated operating voltage: 690V and below
Rated insulating voltage: 750V
Poles: 3, 4P
Utilization category: A
| Main Technical Specifications |
![]() |
| Trip units main technical parameter | |||||||||||||||
| Thermal magnetic release | |||||||||||||||
![]() |
|||||||||||||||
![]() |
|||||||||||||||
| ?Electronic release | |||||||||||||||
| BDM2 22SE: protection of low-voltage distribution networks for BDM2-100160250 | |||||||||||||||
![]() |
|||||||||||||||
| 1. Overload protection with adjustable threshold 2. Short-circuit protection with adjustable threshold 3. Load indication : light at 90% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold |
|||||||||||||||
![]() |
|||||||||||||||
| BDM2 22ME: protection of motor for BDM2-100160250 | |||||||||||||||
![]() |
|||||||||||||||
| 1. Overload protection with adjustable threshold, as defined by IEC60947-4 (2) tripping class 10 2. Short-circuit protection with fixed threshold (13xIr) 3. phase failure protection (tripping time delay between 3.5s-6s) 4. Load indication : dark less than 105% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold |
|||||||||||||||
![]() |
|||||||||||||||
| BDM2 23SE: protection of low-voltage distribution networks for BDM2-400630 | |||||||||||||||
![]() |
|||||||||||||||
| 1. Overload protection with adjustable threshold 2. Short-circuit protection with adjustable threshold 3. Load indication : light at 90% of Ir setting threshold; Flashing at 105% or more of Ir setting threshold |
|||||||||||||||
![]() |
|||||||||||||||
![]() |
|||||||||||||||
| 1. Overload protection with adjustable threshold, as defined by IEC60947-2 2. Short-circuit protection with adjustable threshold 3. Instantaneous short-circuit protection 4. Earth fault protection with adjustable threshold 5. Load indication : light at 90% of Ir setting threshold; Flashing more than Ir setting threshold 6. Fault indication LEDs indicates the type of fault that caused tripping Overload (LT protection) or abnormal component temperature (>Ir); Short-circuit (ST or instantaneous protection)( >Im); Earth fault (if earth fault protection option is present)(Ig); Microprocessor malfunction (both (>Ir) and ( >Im) LEDs go on ,plus the (Ig) LEDs if earth fault protection option is present ) Battery powered. Spare battery are supplied in an adapter box. When a fault occurs , the LED indicating the type of fault ,lights for about 10 minutes . The information is however stored in memory . The LED can be illuminated by pressing the test pushbutton. The LED automatically goes off and the memory is cleared when the circuit breaker is reset . |
|||||||||||||||
![]() |
|||||||||||||||
| BDM2 43ME: protection of motor for BDM2-400630 | |||||||||||||||
![]() |
|||||||||||||||
| 1. Overload protection with adjustable threshold, as defined by IEC60947-4 (2) tripping class 10A,10 and 20 2. Short-circuit protection with adjustable threshold (6...13xIr) 3. Phase failure protection (built-in electronic release: operates unbalanced single-phase currentat 40% and more than )(tripping time delay 4s?0%),as defined by IEC60947-4.1 4. Load indication : Flashing more than Ir setting threshold 5. Fault indication LEDs indicates the type of fault that caused tripping Overload (LT protection) or abnormal component temperature (>Ir); Short-circuit (ST or instantaneous protection)( >Im); Phase failure (right LED); Microprocessor malfunction ( (>Ir) ( >Im) and phase failure LEDs all go on ) Battery powered. Spare battery are supplied in an adapter box. When a fault occurs ,the LED indicating the type of fault ,lights for about 10 minutes . The information is however stored in memory . The LED can be illuminated by pressing the test pushbutton. The LED automatically goes off and the memory is cleared when the circuit breaker is reset . |
|||||||||||||||
|
| Payment Terms | L/C, T/T |
|---|---|
| Minimum Order | NO LIMIT |
| Lead Time / Delivery Time | 10 Day(s) |
| Sample Available | YES |
| FOB Port | Ningbo,Wenzhou |
| Loading Info | By sea or by air |
| Packing Info | Standard export carton or according to the customer's requirements |
| Target Market(s) | Africa, Eastern Europe, Latin America, Mainland China, Middle East, Northern Europe, Oceania, South Asia, Southeast Asia, Western Europe |
Related products
NS 1600N Moulded Case Circuit Breaker
Model Number: Circuit Breaker - 005
NS 1600N Moulded Case Circuit Breaker Comply with IEC60947-2,Up to 1600Amp Thermal Magnetic 3p and 4p
BDPX125 Moulded Case Circuit Breaker
Model Number: Circuit Breaker - 001
BDPX125 Moulded Case Circuit Breaker Comply with IEC60947-2,Up to 800Amp Thermal Magnetic 3p,4p
3Pole NS 400N MCCB
Model Number: Circuit Breaker - 003
3Pole NS 400N MCCB Comply with IEC60947-2,Up to 1600Amp Thermal Magnetic 3p and 4p